Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Przeglądasz jako GOŚĆ
Zmień bibliotekę
Tytuł pozycji:

Could Negative Tc-99m-Methoxyisobutylisonitrile (MIBI) Scintigraphy Obviate the Need for Surgery for Bethesda III and IV Thyroid Nodules?

Tytuł :
Could Negative Tc-99m-Methoxyisobutylisonitrile (MIBI) Scintigraphy Obviate the Need for Surgery for Bethesda III and IV Thyroid Nodules?
Autorzy :
Stella Armefti
Jasmin Mettler
Matthias Schmidt
Michael Faust
Marianne Engels
Anne M. Schultheis
Costanza Chiapponi
Pokaż więcej
Temat :
99mcTc MIBI scintigraphy
fine needle aspiration cytology
Bethesda III and IV
diagnostic hemithyroidectomy
Surgery
RD1-811
Źródło :
Surgeries, Vol 2, Iss 26, Pp 260-267 (2021)
Informacja o wydawcy :
MDPI AG, 2021.
Rok publikacji :
2021
Typ dokumentu :
article
Opis pliku :
electronic resource
Język :
English
ISSN :
2673-4095
Relacje :
https://www.mdpi.com/2673-4095/2/3/26; https://doaj.org/toc/2673-4095
DOI :
10.3390/surgeries2030026
Dostęp URL :
https://doaj.org/article/20dd06f8e7b74012bdf597ce5ca070d0
Numer akcesji :
edsdoj.20dd06f8e7b74012bdf597ce5ca070d0
Czasopismo naukowe
In about 20% of all cases, the fine needle aspiration cytology (FNAC) results are equivocal, delivering the two common categories of indeterminate cytology, Bethesda III and IV. The observed rates of malignancy vary widely among institutions, with the urgent need for a more precise risk stratification. 99mcTc methoxyisobutylisonitrile scintigraphy (MIBI) is less expensive than molecular testing and has been shown to have a high negative predictive value. For this reason, the results of MIBI scintigraphy in adult patients with indeterminate FNAC were collected, and correlated with the final pathology reports of surgical specimens. Patients receiving FNAC, MIBI scintigraphy and surgery for sonographic suspicious hypofunctional thyroid nodules between 2015 and 2019 at the University Hospital of Cologne, Germany were identified. Sensitivity, specificity, positive predictive and negative predictive value of MIBI scintigraphy were calculated. Seventy-eight patients with sonographic suspicious hypofunctional thyroid nodules underwent surgery after interdisciplinary case discussion of both FNAC and MIBI results. In 49 (62.5%) cases, FNAC consisted of Bethesda III and IV results. In 39 (79.6%) of these cases, MIBI scintigraphy resulted in mismatch and intermediary results, but in only 4 (10.2%) of these cases was a carcinoma diagnosed. The negative predictive value of MIBI scintigraphy was 90–100%, respectively. Relying on the negative predictive value of MIBI match results might have obviated the need for surgery in 20.4% cases; one papillary microcarcinoma, however, would have been missed. MIBI scintigraphy has an underused potential for improving the diagnostic precision of hypofunctional thyroid nodules.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies